KleoQC. ACCURACY SAVES LIVES

Often displays used for diagnosis and reviewing of medical images are not up to industry quality standards. It is of course every healthcare professional's responsibility to provide patients with the highest possible level of care, but regardless of the skill of your organization's practitioners, their performance will suffer from poorly-calibrated medical imaging displays.
Medical professionals need to see all the detail on their screens that is captured by imaging technologies such as X-rays or CR/DR (computed radiography/digital radiography) - the two ways to acquire X-rays - MRIs (magnetic resonance imaging), ultrasound and CTs (computed tomography).
More than an isolated occurrence, improperly-calibrated medical displays are actually a common industry problem that affects not only the quality of the treatment your organization provides, but can result in life-threatening situations that could have been avoided simply and affordably.
1. Image Acquisition: Images are acquired through the system.
2. Image Processing: The image is optimally presented for interpretation by the diagnostician.
3. Display Quality: Determines how accurately the resulting images are interpreted.
If any of these areas fail to meet standards, it is very likely that the quality of the resulting medical treatment will be impacted.
That’s why we created KleoQC
KleoQC performs the "Standard Acceptance Test" so you can be assured that your display's image quality is up to standards and that those standards are maintained throughout its useful life.
KleoQC supports DIN6868-57, AAPM TG18 and IEC standards.
DIN 6868-57: Deutsches Institute fur Normung-German Standard Institute.
This standard describes the performance of acceptance and conformance tests used to determine the quality of the image display devices. DIN describes the parameters and tools to be used for acceptance and conformance testing.
Both the manufacturer and user/expert should perform such an acceptance test upon installation or after modifications that could influence image quality and should determine the reference values. Based on the performance of the display, the test has to be performed regularly as per the schedule described in the standard.
KleoQC provides this standard with a wizard-based user interface making it quick and easy to run the tests described in DIN6868-57 standards
AAPM TG18: American Association of Physicists in Medicine Task Group 18.
This standard provides guidelines to practicing medical physicists, engineers, researchers and radiologists for the performance evaluation of electronic display devices intended for medical use.
It outlines both acceptance testing and quality control. Acceptance testing is required before the first use of a diagnostic imaging device, and each time after it has been repaired or replaced. Quality control specifies periodic, recurring check-ups during the use of medical devices.
KleoQC provides this standard with a wizard based user interface making it quick and easy to run the tests described in AAPM TG18: standards.
IEC 61223-2-5-International Electrotechnical Commission.
"Evaluation and Routine Testing in Medical Imaging Departments - Part 2-5" established by the International Electrotechnical Commission (IEC).
The IEC is a worldwide organization for standardization comprising all national Electrotechnical committees (IEC National committees). This standard describes the acceptance and constancy test for image display devices used in the medical electrical equipments and systems for diagnostic imaging.
KleoQC provides this standard with a wizard based user interface making it quick and easy to run the test described in IEC standard.
QUBYX provides these value-added features for KleoQC users:
* Performs DIN 6868-57, AAPM TG-18 and IEC Acceptance testing.
* Supports grayscale and color displays.
* Supports multi sensors.
* Supports multi displays.
* It allows the user to view the Luminance Response Graph
* A detailed history report produced for each DIN, AAPM and IEC standards test results are shown with the user option to preview and print the report. A PDF format of this detailed report is also generated, which can be saved for future review.
* KleoQC supports Wellhoefer Lxplus photometer, Xrite and Eye-one sensors.
* KleoQC provides the user with a method for entering the measurement values manually, even if your measurement device is not supported.
* The KleoQC History Report lets the user to check the results and compare their quality with all the earlier performed acceptance test results of any previous dates on all the performed workstation displays.
The key features in KleoQC Administrator:
* Remote actions: Actions can be performed remotely on workstations connected to KleoQC administrator.
* Alert Mailings: Users or technicians can immediately receive an email notice whenever a tested monitor fails to meet standards.
* Schedule: Tasks can be scheduled to run automatically on any monitors that are connected to the KleoQC administrator.
* History: The KleoQC administrator history gives complete information about the different tasks performed by the client.
Product Overview:
QUBYX KleoQC is a quality acceptance software capable of performing quality acceptance and conformance tests based on DIN 6868-57, AAPM TG18 and IEC standards.
Check out for some of the key features of KleoQC:
1. Supports multiple sensors.
2. User can enter measured values manually.
3. Reports can be exported to PDF format.
4. Maintain detailed history of Acceptance test.
5. User can view reference images and AAPM test patterns.